Fuse Combination, High Voltage Indoor Vacuum Load Break Switch,12kV ,IEC62271,GB3804

Product Categories
Zhejiang Fukai Electric Co., Ltd.

Fuse Combination, High Voltage Indoor Vacuum Load Break Switch,12kV ,IEC62271,GB3804

Supply Ability : 100 Set/Sets per Week

MOQ : 5 Set/Sets

Port : NINGBO/SHANGHAI

Packaging Details : Wooden box within nylon bag

Delivery Time : 25DAYS

Price : FOB USD 984~1030 / SetGet Latest Price

Payment Terms : L/C,T/T

Place of Origin : Zhejiang

Brand Name : XIKAI

Rated Current : 630A

Rated Voltage : 12kV

1min Power Frequency Withstand Voltage : 42/48kV

Max. Current : 630A

Max. Voltage : 12kV

Model Number : FN16A-12R

Rated Frequency : 50Hz

Rated Power Load Switch-off Current : 630A

Category : Switches

Contact Now


1.Fuse Combination
2.High Voltage 12kV 50Hz
3. Indoor install
4. Vacuum Load Break Switch
5. Switch off the onload current

Summary

FN16A-12D/630 indoor AC H.V Vacuum load break switch and FN16A-12RD/200-31.5 load switch-fuse combination are developed by our company The products follow GB3804-90 3-62KV AC H.V load switch and IEC62271<AC H.V. indoor load break switch-fuse combinations>(2002 edition). These switches are small volume, beautiful appearances, flexible installation, and easy operation.

Load break switch with-fuse combinations are also used for protecting over load of transformer and avoiding short-circuit current.

-

Main Application

FN16A-12D/load switch and FN16A-12RD/200-31.5 switch-fuse combination are suitable for the power systems with AC 50Hz rated voltage 6-10kv. This switch is suitable for the oil less, less repair and frequent operating equipment.

This switch can match with CS6-1 Operating mechanism; the operator can directly operate on the switch.

The FN16A-12-J switch can operate manually (manual handle) and automatically (motor).

Service condition (Applying ambient conditions)

a.The ambient air temperature Max:+40oC ’Min:-25oC

b.The relative humidity:monthly average ≤ 90% daily average ≤ 95%

c.The altiude does ot exceed 1000m

d.The ambient don’t have corroder and the flammability gas.Etc

e.The working situation without frequent violent

-

Main Technical Information

1.FN16A-12D/630 load break switch-fuse combinations technical data

No.

Description

Unit

Data

1

Rated voltage

KV

12

2

Rated frequency

Hz

50

3

Rated current

A

630

4

Rated breaking capacity for active circuits

A

630

5

Rated closed switch-off current

A

630

6

5% Rated breaking capacity for active circuits

A

31.5

7

Rated cable charging switch-off current

A

10

8

Rated capacity switch-off current

A

400

9

Rated switch-off current of no-load transformer

-

1600VKA current of no-load transformer

10

1min power frequency withstand voltage<value>(to earth and between poles, across vacuum interrupter distance/across isolating distance)

KV

42/48

11

full ware lighting impulse resisting voltage <peak >(to earth and between poles, across vacuum interrupter distance/across isolating distance)

KV

75/85

12

Rated short-time withstand current (heat-steadily)

KVIS

20/3

13

Rated peak withstand current (machine-steadily)

KV

50

14

Rated short-circuit controlled current

KV

50

15

Rated current breaking times

Cycle

10000

16

Mechanical life

Cycle

10000

17

Contact allowed fret thickness

mm

3

18

Switch on-and-off operating moment

-Nm/(N)

120(240)

19

Rated switch-on operate voltage/current

V/A

~220/0.5

20

Rated switch-off operate voltage/current

V/A

~220/3

-

2.FN16A-12RD/200-31.5 load break switch-fuse combination technical data

No.

Description

Unit

Data

1

Rated voltage(the highest working voltage)

KV

12

2

Rated frequency

Hz

50

3

The Max. current of fuse

A

200

4

Rated transfer current

A

3150

5

Switch-off time of fuse stroking switch

ms

310+5

6

Rated short-circuit switch-off current (prospective peak)

KA

31.5

7

Rated short-circuit controlled current (prospective peak)

KA

80

8

1min Power Frequency withstand voltage (value) (to earth. Between poles/across isolating distance)

KV

42/48

9

full wave lighting impulse resisting voltage (peak )(to earth, between poles/Across Isolating Distance)

KV

75/85

10

Fuse striker output energy

J

2-5

-

-


Quality Fuse Combination, High Voltage Indoor Vacuum Load Break Switch,12kV ,IEC62271,GB3804 for sale

Fuse Combination, High Voltage Indoor Vacuum Load Break Switch,12kV ,IEC62271,GB3804 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhejiang Fukai Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)